Guidance 4D probe; acknowledge the probe via the ID code; switch the 4D push sign through the electrical relay to produce the 4D probe operate normally. four.2.two Major board The most crucial board might be divided into two parts: entrance-stop of the primary board and again-close of the principle board.
The user isn't permitted to open the handles and panel in the method, neither NOTE: product disassemble is permitted. To make sure the procedure efficiency and safety, only Mindray engineers or engineers approved by Mindray can complete routine maintenance.
Get a complete and extended see of the anatomical construction by panoramic imaging coupled with velocity indication and forward/backward scan ability generating scanning easier, smoother plus more controllable.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Simply click Concur and Move forward to accept cookies and go on to the location or click on More info to view detailed descriptions of the kinds of cookies and pick irrespective of whether to accept specified cookies though on the positioning.
Mindray’s new technology of black & white ultrasound procedure, DP-fifty Pro, is provided with Sophisticated imaging technologies letting deeper penetration and speedier graphic acquisition with increased resolution.
Site 145 Cleanse control panel Equipment: dry delicate cloth, moderate soapy water Process: Use dry comfortable fabric to clean the area from the program. Should the method is dirty, moisten the comfortable cloth with gentle soapy drinking water and wipe off any stains. Use dry comfortable fabric to get rid of any dampness and permit all hard surfaces to totally air-dry. Webpage 146: Clear The Peripherals
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
Permits usage of various scanned angles to form an individual graphic, causing Improved distinction resolution and improved visualization
Our DP-fifty Rated units can withstand hurricane-pressure winds up to 173 mph. Committed to supplying master Wooden entry doors to states with even the strictest constructing prerequisites, DP-50 Rated Models are DSA’s minimum amount Coastal Door Ranking which satisfies or exceeds most non-impression building prerequisites along the east coast.
Immediately after prosperous connection, the freshly added network printer title is going to be shown during the printer driver checklist. NOTE: Right before link the network printer, ensure that the ultrasound program along with the printer are in exactly the same Dp50rb login network domain, as well as the community is Doing work Usually. The IP deal with as well as server name need to be valid, e.g. Web site forty seven DICOM Location Enter the AE Title from the ultrasound technique, port and PDU in accordance with the precise scenario, then click on [Okay] to exit the display screen.
.. Web site 161 The indicator on the printer Errors happen once the adapter turns orange, plus the printing printer adapter runs. Disconnect and connect the fails. electrical power adapter, electricity about the printer adapter once again, and validate if the printing is regular following one minute. Page 163: Electrical Basic safety Inspection
Observe: Prior to inserting the connector to the probe port, inspect the connector pin. If the pin is bent, don't make use of the probe until finally it's been inspected / fixed / changed. Installing Peripherals With the types with the supported peripherals, be sure to refer to “2.
Immediately after changing the CPU module, critical file needs to be produced Again based on the new MAC address and written into HDD from the equipment. Or else, the configuration perform with the product is going to be shed. Right after taking away the CPU module, Remove panhead screws with washers (twelve M3X6) preset on the key unit box, you can take from the board. Webpage 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Maintain the upper fringe of user interface assembly, and open up up the user interface. Determine eight-thirty Disassemble the Control Panel Assembly (2) Soon after taking away one countersunk head self-tapping screw PT3X10 fixed within the control panel and consider out the plug of the keyboard and the most crucial unit connecting cables, you may clear away the control panel assembly.
Notice: Guantee that you could pull out and force in the IO board sockets vertically when pulling out and assembling the IO board assembly about the place on the tackle. Get rid of panhead screws with washers M3X6 (four) used to protected the IO board, and after that you could choose out the IO board. Webpage 116 Eliminate panhead screws with washers (2 M3X6) that are mounted on the leading device, choose out the upper baffle and then pull out two cables connecting the leading board to the ability module assembly.